Accessibility

Our global life sciences company brings diagnostic testing & drug development together.

Labcorp.com

Inheritest® Carrier Screen, Society-guided Panel (14 Genes)

CPT: 81200; 81209; 81220; 81242; 81243; 81251; 81255; 81257; 81260; 81290; 81329; 81330; 81361
Print Share

Synonyms

  • Pan-ethnic Carrier Screening

Test Includes

Screening for 14 genes, including fragile X carrier screening and spinal muscular atrophy (SMA) carrier screening. This test includes: ASPA, BLM, CFTR, FANCC, FMR1, GBA, HBA1, HBA2, HBB, HEXA, IKBKAP, MCOLN1, SMN1 and SMPD1.


Special Instructions

Test orders must include an attestation that the provider has the patient's informed consent for genetic testing. See sample physician office consent form: Consent for Genetic Testing. Call Integrated Genetics at 855-422-2557 to obtain access to genetic counseling.


Expected Turnaround Time

11 -14 days




Specimen Requirements


Specimen

Whole blood


Volume

8.5 mL


Container

Yellow-top (ACD-A) tube (preferred) or lavender-top (EDTA) tube; yellow-top (ACD-B) tube is not acceptable


Storage Instructions

Maintain specimen at room temperature or refrigerate at 4°C.


Causes for Rejection

Frozen specimen; hemolysis; quantity not sufficient for analysis; improper container; blood specimens more than four days post draw


Test Details


Use

Carrier testing by analyzing 14 genes for more than 1,200 pathogenic variants associated with more than 13 autosomal recessive or X-linked disorders including fragile X syndrome and spinal muscular atrophy.


Limitations

SMN1 copy number analysis does not detect individuals who are carriers of SMA as a result of germline mosaicism; or small intragenic variants within the SMN1 gene; or variants in genes other than SMN1.

Technologies used do not detect germline mosaicism and do not rule out the presence of large chromosomal aberrations, including rearrangements, or variants in regions or genes not included in this test, or possible inter/intragenic interactions between variants. Variant classification and/or interpretation may change with time if more information becomes available. False-positive or false-negative results may occur for reasons that include: genetic variants, technical handling, blood transfusions, bone marrow transplantation, mislabeling of samples, or erroneous representation of family relationships.

This test was developed and its performance characteristics determined by Esoterix Genetic Laboratories LLC. It has not been cleared or approved by the Food and Drug Administration.


Methodology

Next generation sequencing (NGS): Genomic regions of interest are selected using the Agilent® SureSelectXT® hybridization capture method for target enrichment and sequenced via the Illumina® next generation sequencing platform. Sequencing reads are aligned with the human genome reference GRCh37/hg19 build. Targeted regions are sequenced to at least 200X mean base coverage with a minimum of 99% of bases at > or = 20X coverage. Analytical sensitivity is estimated to be >99% for single nucleotide variants and small insertions/deletions (<5 bp).

Alpha-thalassemia: Analysis of the alpha-globin (HBA) gene cluster is performed by multiplex ligationdependent amplification (MLPA). Variants included in the analysis are the Constant Spring non-deletion variant and the following deletions: -alpha3.7, -alpha4.2, -alpha20.5, --SEA, --FIL, --THAI, --MED, and the HS-40 regulatory region. This MLPA analysis does not detect other variants in the alpha-globin genes or variants in the beta-globin gene and may not detect the co-occurrence of a deletion and a duplication. Analytical sensitivity is estimated to be >99% for the targeted variants.

Spinal muscular atrophy: The copy number of SMN1 exon 7 is assessed relative to internal standard reference genes by quantitative polymerase chain reaction (qPCR). A mathematical algorithm calculates 0, 1, 2 and 3 copies with statistical confidence. When no copies of SMN1 are detected, the primer and probe binding sites are sequenced to rule out variants that could interfere with copy number analysis and SMN2 copy number is assessed by digital droplet PCR analysis relative to an internal standard reference gene. Individuals with one copy of SMN1 are predicted to be carriers of SMA; those with two or more copies have a reduced carrier risk. For carrier screening, when two copies of SMN1 are detected, allelic discrimination qPCR targeting c.*3+80T>G in SMN1 is performed. The presence or absence of c.*3+80T>G correlates with an increased or decreased risk, respectively, of being a silent carrier (2+0).1,2

Fragile X syndrome: DNA is amplified by the polymerase chain reaction (PCR) to determine the size of the CGG repeat region within the FMR1 gene. PCR products are generated using a fluorescence labeled primer and sized by capillary gel electrophoresis. If indicated, Southern blot analysis is performed by hybridizing the probe StB12.3 to EcoRI- and EagI-digested DNA. The analytical sensitivity of both Southern blot and PCR analyses is 99% for expansion mutations in the FMR1 +/- one for repeats less than 60, and +/- two to four for repeats in the 60 - 120 range. For repeats greater than 120, the accuracy is +/- 10%. If 55-90 trinucleotide repeats are detected in carrier screening females, a PCR assay targeting AGG sequences within the CGG repeats is performed to assess the number and position of AGG interruptions.

Reported variants: Pathogenic and likely pathogenic variants are reported. Nondeletion variants are specified using the numbering and nomenclature recommended by the Human Genome Variation Society (HGVS). Variants of uncertain significance and benign variants are not reported. Variant classification and confirmation are is consistent with ACMG standards and guidelines.3,4 Detailed variant classification information is available upon request.


Footnotes

1. Luo M, Liu L, Peter I, et al. An Ashkenazi Jewish SMN1 haplotype specific to duplication alleles improves pan-ethnic carrier screening for spinal muscular atrophy. Genet Med. 2014 Feb;16(2):149-156.23788250
2. Feng Y, Ge X, Meng L. et al. The next generation of population-based spinal muscular atrophy carrier screening: comprehensive pan-ethnic SMN1 copy-number and sequence variant analysis by massively parallel sequencing. Genet Med. 2017 Aug;19(8):936-944.28125085
3. Richards S, Aziz N, Bale S, et al. Standards and guidelines for the interpretation of sequence variants: a joint consensus recommendation of the American College of Medical Genetics and Genomics and the Association for Molecular Pathology. Genet Med. 2015 May;17(5):405-424.25741868
4. Rehm HL, Bale SJ, Bayrak-Toydemir P, et al. ACMG clinical laboratory standards for next-generation sequencing. Genet Med. 2013 Sep;15(9):733-747.23887774

LOINC® Map

Order Code Order Code Name Order Loinc Result Code Result Code Name UofM Result LOINC
451960 Inheritest Society Guided 451999 Genetic Counselor: NGS Inheri n/a
451960 Inheritest Society Guided 451997 Specimen Type: InheriTest 31208-2
451960 Inheritest Society Guided 451998 Ethnicity: InheriTest 42784-9
451960 Inheritest Society Guided 451618 Indication: 42349-1
451960 Inheritest Society Guided 451846 Society Guided Results: 53039-4
451960 Inheritest Society Guided 451613 General Comments: n/a
451960 Inheritest Society Guided 451616 Additional Clinical Info 55752-0
451960 Inheritest Society Guided 451384 Comments: 77202-0
451960 Inheritest Society Guided 451386 Method/Limitations: 49549-9
451960 Inheritest Society Guided 451614 Information Table 36908-2
451960 Inheritest Society Guided 451333 Disclaimer: n/a
451960 Inheritest Society Guided 451612 Director Review: 72486-4
451960 Inheritest Society Guided 451743 PDF 51969-4

For Providers

Please login to order a test

Order a Test

© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.

CPT Statement/Profile Statement

The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf