Skip to main content

Uranium, Urine

CPT 83018

Test Details

Methodology

Inductively coupled plasma/mass spectrometry (ICP/MS); spectrophotometry (SPEC)

Result Turnaround Time

5 - 9 days

Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary.

Use

Evaluate exposure to uranium

Specimen Requirements

Specimen

Urine (random)

Volume

10 mL

Minimum Volume

0.5 mL

Container

Metal-free plastic urine container or metal-free transfer tube

Reference Range

Unexposed population: <1.0 µg/24 hours

Exposed: levels of 100 ng/mL are indicative of recent exposure to at least 50 µg/m³.

Storage Instructions

Submission/transport (<3 days): Room temperature. For storage beyond three days, specimen should be refrigerated or frozen.

Causes for Rejection

Use of non−metal-free collection containers or tubes

LOINC® Map

Order Code Order Code Name Order Loinc Result Code Result Code Name UofM Result LOINC
808567 Uranium, Urine 808571 Uranium, Urine ng/ml 5752-1
Order Code808567
Order Code NameUranium, Urine
Order Loinc
Result Code808571
Result Code NameUranium, Urine
UofMng/ml
Result LOINC5752-1